• DN500 5KW Power Frequency Solar Inverter

  • Đăng ngày 20-05-2024 09:56:18 PM - 22 Lượt xem
  • Mã sản phẩm: S000016
  • Giá bán: Liên hệ
  • Brand: Lersion

    Product origin: China

    Supply capacity: 200000

    1 Power frequency scheme design
    2 The inverter adopts MCU microprocessor fully digital SPWM control technology, with pure sine wave output.
    3 Pure sine wave output.
    4 Residencial energy storage best solution choice.


1 Product Featrues:

  • Power frequency scheme design, pure sine wave output, suitable for various types of loads;

  • Ring type transformer, low loss while no-load;

  • Wide input voltage range and high-precision output;

  • Three mode can be set, battery type, charging voltage and current configurative.

  • Battery overvoltage / low voltage, overload, short circuit, over temperature protection, etc;

  • Built in MPPT controller, higher charging efficiency;

  • It can be used as unattended function and more humanized;

  • Lightning arrester can be installed (optional);

  • Built in or external WiFi monitoring (optional);

  • LCD screen design, more accurate and intuitive display and simple operation;

 

2 Application

 

power frequency solar inverter pure sine wave solar inverter single phase solar inverter power frequency solar inverter pure sine wave solar inverter single phase solar inverter

Residential 

electricity 

Communication 

base station 

Ship/Island

Animal

husbandry 

Non grid area Field equipment 

power frequency solar inverter

3 Technical Parameters

Inverter mode DN150 DN200 DN300 DN400 DN500 DN600
Inverter with 
controller mode
DM150 DM200 DM300 DM400 DM500 DM600
Rated power 1500W 2000W 3000W 4000W 5000W 6000W
Battery voltage 24V/48V 48V
Size:(L*W*Hmm) 430*320*175 560*400*200 / 560*450*230(100A)
package size
(L*W*Hmm)
500*390*245 630*470*270 / 630*520*300(100A)
N.W.(KG) 15 20 22 27 29 31
G.W.(KG) 17 23 25 30 32 34
Input
Phase L+N+G
AC input range 110V:85-138VAC;220V:170-275VAC
Input frequency 45Hz~65Hz
Output
Output voltage inverter mode:110VAC/220V±5%;AC mode:110VAC/220VAC±10%;
Frequency range
(AC mode)
Automatic tracking
Frequency range
(inverter mode)
50Hz/60Hz±1%
Over load capacity AC mode:(100%~110%:10min;110%~130%:1min;>130%:1s;)
inverter mode:(100%~110%:30s;110%~130%:10s;>130%:1s;)
Peak current ratio 3:1max
Conversion time <10ms(Typical loads)
Waveform Pure sine wave
Efficiency >93%(80% resistive loads)
Protection 
functions
Battery overvoltage protection,battery undervoltage protection,overload protection,
short circuit protection,overtemperature protection,etc.
built in solar charge controller(adjust)
Max charge current 40A 50A 60A 100A 120A  
Battery voltage 24V/48V 24V/48V 24V/48V 24V/48V 24V/48V  
PV input voltage 
range
24V:38V-150V;48V:65V-150V;96V:145V-200V
Max PV input 24V:960W
48V:1920W
24V:1200W
48V:2400W
24V:1440W
48V:2880W
24V:2400W
48V:4800W
24V:2880W
48V:5760W
 
Cooling method Fans cooling
environmental conditions
Operating 
temperature
0℃-40℃
(Battery life decreases at ambient temperatures above 25 degrees Celsius)
Operation humidity <95%(without condesing)
Operating altitude <1000m(with increase of 100m,it will reduce output of 1%) max5000m
Noise <58dB(distance to machine 1m)
Management
Display LCD+LED
Computer 
communication 
interface
RS232(adjust)
*The above data is for reference. If there is any change, please refer to the real object.

4 Working mode

D series single phase inverter transformer based unit has three working modes:

DC priority, AC priority, ECO mode

4.1 DC Priority (Must be connected with batteries) 

The inverter converts DC input current from either the PV panels or battery bank into AC current to supply the load. When battery voltage is low, the inverter will automatically switch to the main input power (gr/generator) to supply to the load. The system automatically switches back to DC after the batteries are charged again.

4.1.1 PV with battery bank (when PV is sufficient)

pure sine wave solar inverter

4.1.2 Battery only (when PV is not available, but battery power is sufficient)

single phase solar inverter

4.1.3 AC only (when PV is not available, and battery power is insufficient)

power frequency solar inverter

4.2 AC Priority (must be connected with batteries)

While the AC input is stable, the inverter works in bypass mode to supply power to the load and charge the battery pack at the same time. When the AC input is too high / too low / serious distortion / abnormal frequency / fault, the system will automatically switch to the battery inverter to supply power to the load. Once the AC input has been stabilized, the system will switch back to bypass mode to supply power to the load automatically

4.2.1 PV is sufficient, AC power is available

pure sine wave solar inverter

4.2.2 PV is sufficient, but AC power is not available

single phase solar inverter

4.2.3 AC power is available but PV is not available

power frequency solar inverter

4.2.4 Both AC power and PV are not available

pure sine wave solar inverter

Bạn đã không sử dụng Site, Bấm vào đây để duy trì trạng thái đăng nhập. Thời gian chờ: 60 giây